This document describes how to identify RI8586A3 25 GHz Source with capacitor issue with the Rev B boards, does not apply to later revisions. The Source# instrument does not output any power above -50 dBM and the TIM fan does not operate.
URGENCY: Low. Repair as failure occurs.
SYMPTOMS
No Power Out. TIM Fan not running.
Unit will not power up on bench, debug finds +15V SMPS is in current limit and is cycling. tracing issue to Apria M24-NG Rev B module. Found 2nd capacitor at pwr input pi filter is ohmatic (12ohms) but not shorted 100%
CORRECTIVE ACTION REQUIRED
Replace affected components with 4 10uF 50V ceramic capacitors. Contact Support ([email protected]) for specific instructions for diagnosing or replacing malfunctioning items.

RZM2JP0A - 6/13/2024
RXLGPY0A - 11/13/24
RXLGPG0A - 11/13/24
RYN8FC0A - 11/13/24
To Do
RXVGU20A - proposed
RXVGW10A - proposed
RYN8980A - proposed
RYW32A0A
RXGVYT0A
RXL8AP0A