Purpose: To describe in one document the current and voltages needed to drive each of the available fixture modules. Test conditions are set for maximum current drain.
| Module RIK#  | Module  Description Fab#  |  Test Conditions  | I Drain 5V Typ  | I Drain -5V Typ  | I Drain 12V Typ  | I Drain -12V Typ  | I Drain 3.3V Typ  | 
RIK0006A or B  | Dual SPDT Switch  Y0002UB1  | Both switches in NO position | 0.9mA  | ||||
RIK0013B  | Smart Carrier Y0002AC1  | Idle -No modules installed | 140mA  | 0mA  | |||
RIK0014B  | Smart Carrier 12RF Y0004VA1  | Idle -No modules installed | 130mA  | 0mA  | |||
 RIK0015A  | Diff I/O  Y0002OB1  | -11 dBm at input  | 80 mA  | 50 mA  | |||
RIK0017A  | High Speed Dig Y000LB3 Y0004NB1  | Idle  | 51ma  | 0ma  | |||
RIK0026B  | SPDT Switch Y00036C1  | Both switches in NO position | 0.9mA  | 0mA  | |||
RIK0054B  | 3GHz Divider/ SPDT Y0005HB0  | Divider Fully Enable to 256 divide ratio.Switch set to NO | 32mA  | 2.5mA  | |||
RIK0055A  | SPDT/High Pass Filter Y0005NA1  | Both switches to Low | 2mA  | 0mA  | |||
RIK0056A  | SP4T Switch Y0004TB1  | Both switches in full NO position | 9mA  | 0mA  | |||
RIK0058A  | SPDT Switch Y0004CC1  | Both switches in NO position | 2mA  | 0mA  | |||
 RIK0059A  | Step Atten &  LNA Y0004MA1  | Needs Data  | Needs Data  | Needs Data  | Needs Data  | ||
RIK0077A  | HBW Diff I/O Y00062A1  | -11 dBm at input  | 70 mA  | 70 mA  | |||
| RIK0084A | Smart Carrier 20/30RF Y00065A1  | Idle -No modules installed | 170 ma  | 0mA  | |||
RIK0088A  | 1X32, 2X16 DC Mux  | No Connections  | 20 ma  | 6 ma  | 3 ma  | ||
RIK0092A  | 4 Step Attenuator  | 0dB Step  | 1 ma  | 6 ma  | |||
| RIK0127A |   HS Digital Scan Y0008NA1  | Scan Mode  | 120 ma  |  0 ma  | |||